1.
Braz. dent. sci ; 26(4): 1-6, 2023. tab
Article in English | LILACS, BBO | ID: biblio-1523135

ABSTRACT

Objective: Compare the pH values and calcium ion release of calcium hydroxide-based liner materials before and after light-curing. Material and Methods: The materials evaluated were: hydrox-cal white (HW), hydrox-cal dentin (HD), Biocal (BC) and UltraBlend Plus (UB). 120 samples of the liner materials were inserted into a PVC tube (n=15). The samples from HW+A, HD+A, BC+A and UB+A were subjected to photoactivation. The other groups HW+N, HD+N, BC+N and UB+N were only inserted in a glass tube with deionized water. The pH was measured 24 hours and 14 days after the inclusion of the samples with the aid of a pH meter. The calcium release was analyzed with the aid of an atomic absorption spectophotometer at 24h and 14 days. The results were submitted to the Shapiro-Wilk test, followed by ANOVA and Tukey test (p=0.05). Results: In 24h, the groups that were not light cured showed the highest pH values (p<0.05). In 14 days, BC+N and BC+A demonstrated the lowest pH values. The groups that were not light cured also showed higher calcium release values in 24h and 14 days (p<0.05). Conclusion: Photoactivation of calcium hydroxide-based liner materials negatively interferes with calcium ion release, as well as with pH.(AU)


Objetivo: Comparar os valores de pH e liberação de íons cálcio de materiais forradores à base de hidróxido de cálcio antes e depois da fotopolimerização. Material e métodos: Os materiais avaliados foram: Hidrox-cal branco (HW), Hidrox-cal dentina (HD), Biocal (BC) e UltraBlend Plus (UB). 120 amostras dos materiais de revestimento foram inseridas em um tubo de PVC (n=15). As amostras de HW +A, HD+A, BC+A e UB+A foram submetidas à fotoativação. Os demais grupos HW +N, HD+N, BC+N e UB+N foram inseridos apenas em um tubo de vidro com água deionizada. O pH foi medido 24 horas e 14 dias após a inclusão das amostras com o auxílio de um medidor de pH. A liberação de cálcio foi analisada com o auxílio de um espectrofotômetro de absorção atômica em 24h e 14 dias. Os resultados foram submetidos ao teste de Shapiro-Wilk, seguido de ANOVA e teste de Tukey (p=0,05). Resultados: Em 24h, os grupos não fotopolimerizados apresentaram os maiores valores de pH (p<0,05). Em 14 dias, BC+N e BC+A apresentaram os menores valores de pH. Os grupos não fotopolimerizados também apresentaram maiores valores de liberação de cálcio em 24h e 14 dias (p<0,05). Conclusão: A fotoativação de materiais de revestimento à base de hidróxido de cálcio interfere negativamente na liberação de íons cálcio e no pH (AU)


Subject(s)
Humans , Calcium Hydroxide/chemistry , Light-Curing of Dental Adhesives , Hydrogen-Ion Concentration , Spectrophotometry, Atomic , Materials Testing , Dental Restoration, Permanent
2.
Braz. dent. sci ; 26(1): 1-9, 2023. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1411424

ABSTRACT

Objective: Evaluate the mechanical properties of experimental adhesive models with different photoinitiators (PI) polymerized by LED units of different power densities. Material and Methods: Three groups of adhesive models based on HEMA/BisGMA (45/55) were prepared in association with different PI combinations: G2 (control) ­ 2 PI: 0.5% CQ, 0.5% EDMAB; G3 - 3 PI: 0.5% CQ; 0.5% DMAEMA, 0.5% DPIHP; G4 - 4 PI: 0.5% CQ; 0.5% EDMAB; 0.5% DMAEMA; 0.5% DPIHP. The three formulations were polymerized at two different LED power densities: 550 mW/cm2 and 1200 mW/cm2. The degree of conversion (DC) of adhesive monomers was monitored in situ through the FTIR for 600 s. Specimens were prepared for each formulation for analysis mong adhesive systems (G2

Objetivo: Avaliar as propriedades mecânicas de modelos adesivos experimentais com diferentes fotoiniciadores (PI) polimerizados por unidades de LED de diferentes densidades de energia. Material e Métodos: Três grupos de modelos adesivos baseados em HEMA/BisGMA (45/55) foram preparados em associação com diferentes combinações de PI: G2 (controle) ­ 2 PI: 0,5% CQ, 0,5% EDMAB; G3 - 3PI: 0,5% CQ; 0,5% DMAEMA, 0,5% DPIHP; G4 - 4 PI: 0,5% CQ; 0,5% EDMAB; 0,5% DMAEMA; 0,5% DPIHP. As três formulações foram polimerizadas em duas densidades de potência de LED: 550 mW/cm2 e 1200 mW/cm2. O grau de conversão (DC) dos monômeros adesivos foi monitorado in situ através do FTIR durante 600 s. Amostras foram preparadas para cada formulação para análise de resistência à flexão (FS), módulo de elasticidade (ME), sorção (SOR) e solubilidade (SOL). Os dados foram submetidos aos testes ANOVA 2-fatores e Tukey (5%). Resultados: DC: houve diferença significativa entre os sistemas adesivos (G2

Subject(s)
Radiation , Dentin-Bonding Agents , Light-Curing of Dental Adhesives , Photoinitiators, Dental
3.
Odovtos (En línea) ; 24(3)dic. 2022.
Article in English | LILACS, SaludCR | ID: biblio-1406163

ABSTRACT

Abstract This study evaluates the effect of curing modes and times on the mechanical properties of nanocomposites. Two nanocomposite resins were investigated: suprananohybrid (Estelite Posterior Quick; EP) and nanohybrid (Solare X; SX). They were polymerized with a light-emitting diode light-curing units (LED LCU, Valo) as follows: standard mode for 20s (ST20), high power mode for 12s (HP12), high power mode for 20s (HP20), extra power mode for 6s (XP6), and extra power mode for 20s (XP20). For Vickers microhardness (HV), disc-shaped specimens were fabricated (n=10). For the three-point bending test, bar-shaped specimens were fabricated (n=10). Flexural strength and resilience modulus were calculated. The fractured surfaces and specimen surfaces of composites were observed using scanning electron microscopy. The data were analyzed with repeated measures ANOVA, two-way variance, and Bonferroni tests (p<0.05). On the top and bottom surfaces of the EP nanocomposite resin, ST20 and HP12 revealed statistically higher HV than with XP6. Moreover, HP20 and XP20 had statistically higher HV than HP12 and XP6. For the SX nanocomposite resin, HP20 had statistically higher HV than HP12. For EP and SX, there were no significant differences in flexural strength and resilience modulus regarding the curing modes and times. Furthermore, SX demonstrated lower mechanical properties than EP. Scanning electron microscopy indicated that both nanocomposites had similar surface appearances. However, with all curing modes and times, SX exhibited layered fractures and more crack formations than EP. Different curing modes and times could influence the microhardness of nanocomposites.


Resumen Este estudio evalúa el efecto del modo y tiempo de fotocurado sobre las propiedades mecánicas de los nanocompuestos. Se investigaron dos resinas nanocompuestas: supra-nanohíbrida (Estelite Posterior Quick; EP) y nanohíbrida (Solare X; SX). Se polimerizaron con unidades de fotopolimerización de diodos emisores de luz (LED LCU, Valo) de la siguiente manera: modo estándar durante 20s (ST20), modo de alta potencia durante 12s (HP12), modo de alta potencia durante 20s (HP20) , modo extra power durante 6s (XP6) y modo extra power durante 20s (XP20). Para la microdureza Vickers (HV), se fabricaron especímenes en forma de disco (n=10). Para el ensayo de flexión de tres puntos, se fabricaron probetas en forma de barra (n=10). Se calcularon la resistencia a la flexión y el módulo de resistencia. Las superficies fracturadas se observaron mediante microscopía electrónica de barrido. Los datos se analizaron con ANOVA varianza de dos vías y pruebas de Bonferroni (p<0,05). En las superficies superior e inferior de la resina nanocompuesta EP, ST20 y HP12 revelaron un HV estadísticamente mayor que con XP6. Además, HP20 y XP20 tenían un HV estadísticamente más alto que HP12 y XP6. Para la resina nanocompuesta SX, HP20 tenía un HV estadísticamente más alto que HP12. Para EP y SX, no hubo diferencias significativas en la resistencia a la flexión y el módulo de resistencia con respecto al modo y tiempo de fotocurado. Además, SX demostró propiedades mecánicas inferiores que EP. La microscopía electrónica de barrido indicó que ambos nanocompuestos son similares en la superficie. Sin embargo, SX exhibió fracturas en capas y más formaciones de grietas que EP. Diferentes modos y tiempos de fotocurado podrían influir en la microdureza de los nanocompuestos.


Subject(s)
Nanocomposites , Light-Curing of Dental Adhesives , Turkey
4.
São Paulo; s.n; 20220531. 171 p.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1370605

ABSTRACT

O primeiro aparelho de arco reto foi introduzido há mais de 40 anos para aumentar a consistência e a eficiência do tratamento ortodôntico. Mais recentemente, a tecnologia de planejamento e manufatura auxiliada por computador (CAD / CAM) tem sido usada para auxiliar o ortodontista na busca do melhor posicionamento dos bráquetes. O objetivo deste ensaio clínico foi investigar a acurácia por meio de avalaliação do paralelismo radicular e diferenças entre as alturas das cristas marginais posteriores entre as técnicas de colagem direta (G1), colagem indireta (G2) e colagem digital(G3). Foi selecionado três grupos homogêneos de pacientes na Clínica de Ortodontia da Faculdade de Odontologia da Universidade de São Paulo. Após arco 0.018x0.025 Copper NiTi, registros completos fazendo o uso de radiografias panorâmicas (RP), reconstruções panorâmicas obtidas de tomografias computadorizada por feixe cônico (RPT) avaliaram paralelismo entre as raízes pelo método visual OGS (Objective Grading System- ABO) e por medidas lineaes em radiografias panorâmicas (RP) e em reconstruções panorâmicas obtidas por tomografias computadorizadas por feixe cônico (RPT). A mensuração das cristas marginais foi realizada fazendo o uso de modelos de gesso (MG) pelo médodo OGS e modelos digitais (MD) por meio de medidas lineares. O tempo dos procedimentos clínicos de instalação do aparelho foi coletado. A análise de dados foi realizadas por apenas 1 avaliador. Os resultados gerais obtidos indicaram que não houve diferenças estatisticamente significativas no Índice de Discrepância ABO ou na avaliação por radiográfica linear entre os grupos assim como nos MG e MD entre os três grupos avaliados (p>0,001). Apesar de numericamente o grupo G3 apresentar melhores resultados, nas análises segmentadas apenas a região anterior inferior mensuradas nas RPTs foi encontrado menor variabilidade no paralelismo entre as raízes no grupo G2 com diferenças estatisticamente significantes (P=0,026). Na região dos caninos foram encontradas menores variabilidades estatisticamente significativas (p<0,001) com o plano anterior em relação ao plano posterior. Com relação ao lado da colagem foram encontradas diferenças estatisticamente significativas (p<0,001) apresentando menor variabilidade do lado esquerdo nas RPTs. O tempo clínico de colagem foi significativamente menor no grupo da colagem digital = 41,1± 11,8; colagem direta = 56,7 ± 7,3 e colagem indireta = 52,8 ± 8,3. (p<0,001). O presente estudo sinaliza que a técnica de colagem de bráquetes realizada com o auxílio do fluxo digital pode ser um excelente recurso a ser utilizado pelos ortodontistas, minimizando o tempo de colagem e, assim como os sistemas convencionais, proporcionando acurácia no posicionamento dos bráquetes, tendo como objetivo a excelência do tratamento ortodôntico.


Subject(s)
Light-Curing of Dental Adhesives
5.
Acta sci., Health sci ; 44: e57616, Jan. 14, 2022.
Article in English | LILACS | ID: biblio-1366131

ABSTRACT

This study evaluated the effect of contamination of composite resins (CRs) handled by undergraduate students during restorative procedures, varying the time (baseline, 30 days and 60 days) and experimental condition (before and after handling, contamination with saliva [positive control] and photoactivation). Eight CR tubes were randomly distributed at the dental clinic and the samples were organized into four groups: CR fragments collected before (GB) and after (GA) the restorative procedure; CR fragments contaminated with saliva (GS) and photoactivated (GP) both collected after the procedure. These 4 groups were evaluated in 3 different times: baseline (after sealing), 30 days and 60 days of use of the CR. Samples that had positive turbidity in Brain HeartInfusion (BHI) broth were sown in BHI and Sabouraud Dextrose (SB) agars for subsequent counting of Colony Forming Units (CFU mL-1). The results showed that the handling was responsible for increasing contamination (p < 0.05) at the baseline (GB [n = 0] and GA [n = 3]), as well as after 30 (GB [n = 1] and GA [n = 6]) and 60 (GB [n = 1] and GA [n = 5]) days of use. Photoactivation was responsible for the reduction for microorganisms in T0 and T60. Additionally, the time use and conservation did not influencethe contamination of CRs. Handling was responsible for the increase of contamination of CR, the photoactivation seems to reduce the number of viable microorganisms and the time of use seems not to potentiate the effect of tube contamination.


Subject(s)
Pollution Indicators , Composite Resins/analysis , Good Manipulation Practices , Light-Curing of Dental Adhesives/instrumentation , Students, Dental , Data Interpretation, Statistical , Environmental Restoration and Remediation , Food Preservatives/analysis , Microbiology/instrumentation
6.
Rev. odontol. UNESP (Online) ; 51: e20210058, 2022. ilus
Article in English | LILACS, BBO | ID: biblio-1377170

ABSTRACT

Introduction: Endodontically treated teeth are usually affected by extensive structure loss requiring the use of intraradicular posts to provide retention and restoration. Objective: An in vitro assessment was performed on the bonding of glass fiber posts to the root dentin. Material and method: Ninety (n = 10) single bovine roots were used in a 3 x 3 x 3 factorial study with subdivided plots: post customization varying the presence and type of resin (without customization, conventional resin, and Bulk Fill resin), light-curing device (Valo, Radii-Cal, Rainbow), and root third (cervical, middle, and apical). Result: For the customization factor, Tukey's test (5%) showed the superiority of the Bulk Fill (8.16 MPa) and Z350 (7.40 MPa) groups compared to the control group (4.92 MPa), without differing from each other. All light-curing devices differed, showing the superiority of Valo (9.36 MPa), Radii (6.96 MPa) as an intermediate, and the inferiority of Rainbow (4.17 MPa). The cervical root third (7.81 MPa) was superior, the apical third was inferior (5.80 MPa), and the middle third (6.88 MPa) was an intermediate without differing from the others. Conclusion: The customization of glass fiber posts increases the bond strength to the root dentin, regardless of the resin used. There was a compromise in the apical third and when using light-curing devices with lower light intensity.


Introdução: Dentes com extensa perda de estrutura podem comprometer a retenção das restaurações ao remanescente dental, onde pinos intraradiculares são indicados. Objetivo: Avaliou-se in vitro a união de pinos de fibra de vidro à dentina radicular em função de diferentes modos de reanatomização, fotopolimerizadores e regionalização radicular. Material e método: Noventa (n=10) raízes bovinas uniradiculares foram usadas num estudo fatorial 3 x 3 x 3 com parcelas subdivididas: Reanatomização do pino, variando a presença e tipo de resina (Sem reanatomização, Resina Convencional e Resina Bulkfill); Fotopolimerizador (Valo, Radii-cal, Rainbow); e Terço radicular (cervical, médio e apical). Resultado: O teste de Tukey (5%) evidenciou para o Fator Reanatomização superioridade dos grupos BulkFill (8.16MPa) e Z350 (7.40MPa) ao grupo Controle (4.92MPa), sem diferirem entre si. Todos os fotopolimerizadores diferiram entre si, com superioridade de Valo (9.36MPa), Radii (6.96MPa) intermediário, e inferioridade de Raiwbow (4.17MPa). O terço radicular cervical (7.81MPa) foi superior e o apical inferior (5.80MPa), com o terço médio (6.88MPa) intermediário e sem diferir dos demais. Conclusão: Conclui-se que a reanatomização de pinos de fibra de vidro aumenta a resistência de união à dentina radicular, independentemente da resina utilizada, havendo prejuízo no terço apical e quando são empregados fotopolimerizadores com menor intensidade luminosa.


Subject(s)
In Vitro Techniques , Cattle , Post and Core Technique , Resin Cements , Dentin , Light-Curing of Dental Adhesives , Photoinitiators, Dental
7.
Pesqui. bras. odontopediatria clín. integr ; 22: e210110, 2022. tab, graf
Article in English | LILACS, BBO | ID: biblio-1422262

ABSTRACT

Abstract Objective: To evaluate the effect of two types of light-curing units (second and third generations) and two types of bulk-fill composite resins with different photoinitiators - Tetric N-Ceram Bulk Fill (TNCB) and Xtra Fil (XTF) on gap formation at the gingival margins of Cl II restorations. Material and Methods: Fifty-six standard Cl II cavities were prepared on the mesial and distal surfaces of premolar teeth, with the gingival margin of the cavities 1 mm apical to the CEJ. The samples were randomly assigned to two groups based on the composite resin type and two subgroups based on the light-curing unit type and restored. After 5000 rounds of thermocycling, gingival margin gap in each sample was measured in µm under an electron microscope at ×2000 magnification. Data were analyzed by two-way ANOVA and Tukey tests (α=0.05). Results: Marginal gaps of TNCB composite resin were significantly smaller than those of XTF composite resin (p<0.001). There were no significant differences between the two light-curing units in each group (p=0.887 with XTF and p=0.999 with TNCB). Conclusion: The gaps at gingival margins of Cl II cavities with TNCB bulk-fill composite were smaller than XTF composite resin. Both composite resins can be cured with both the second- and third-generation LEDs (AU).


Subject(s)
Humans , Bicuspid , Dental Marginal Adaptation , Composite Resins/chemistry , Light-Curing of Dental Adhesives/instrumentation , Photoinitiators, Dental/chemistry , In Vitro Techniques/methods , Microscopy, Electron, Scanning/instrumentation , Analysis of Variance
8.
Rev. odontol. UNESP (Online) ; 51: e20220032, 2022. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1424232

ABSTRACT

Abstract Introduction composite resins are indicated to the reconstruction of proximal walls and the evaluation of properties of flow bulk-fill composite resins exposed to acid challenge is necessary. Objective to evaluate the microhardness and roughness at different depths of photoactivation of bulk-fill flow composites (Filtek Bulk Fill Flow; SureFil SDR Flow; Tetric N Ceram Bulk fill) and conventional composite resin (control, Filtek Z350 XT) subjected to acid challenge. Material and method forty composites brick shaped specimens (3x3x4 mm) were made using a polyacetal matrix. To simulate pH challenges, the samples were immersed in a demineralizing solution. Each sample had Knoop microhardness (KHN) and roughness (Ra) evaluated at three depths (superficial, medium, and cervical), considering the lateral surface of the sample. Data were submitted to Kruskal-Wallis, Friedman's and Dunn's tests with a significance level of 5%. Result comparing the composites among themselves, in superficial (p=0.693), medium (p=0.053) and cervical (p=0.176) regions, there was no difference in the KHN values. There were also no differences in roughness between the composites in superficial (p=0.356), medium (p=0.734) and cervical (p=0.207) regions. Only the Filtek Z350 XT (p=0.027) showed less difference in KHN in the middle region caused by acid challenge. Changes in roughness showed that the greatest difference was at the cervical region for Bulk Fill Flow SDR (p=0.014) and Tetric N-Ceram Bulk Fill (p = 0.003) with an increase after acid challenge. Conclusion after acid challenge, bulk-fill flow composites showed alterations similar to those presented by the conventional nanoparticulate resin composite.


Resumo Introdução as resinas compostas são indicadas para reconstrução de paredes proximais e a avaliação das propriedades das resinas compostas bulk-fill flow expostas ao desafio ácido mostra-se necessária. Objetivo avaliar a microdureza e rugosidade em diferentes profundidades de fotoativação de resinas compostas bulk-fill flow (Filtek Bulk Fill Flow; SureFil SDR Flow; Tetric N Ceram Bulk fill) e convencional (controle, Filtek Z350 XT) submetidas ao desafio ácido. Material e método quarenta amostras retangulares (3x3x4 mm) foram confeccionadas utilizando uma matriz de poliacetal. Para simular o desafio ácido, as amostras foram imersas em uma solução desmineralizante. Cada amostra teve a microdureza Knoop (KHN) e rugosidade (Ra) avaliadas em três profundidades (superficial, média e cervical), considerando a superfície lateral da amostra. Os dados foram submetidos aos testes de Kruskal-Wallis, Friedman e Dunn com nível de significância de 5%. Resultado comparando as resinas compostas entre si, nas regiões superficial (p=0,693), média (p=0,053) e cervical (p=0,176), não houve diferença nos valores de KHN. Também não houve diferenças na rugosidade entre os materiais nas regiões superficial (p=0,356), média (p=0,734) e cervical (p=0,207). Apenas o Filtek Z350 XT (p=0,027) apresentou menor diferença de KHN na região intermediária causada pelo desafio ácido. As mudanças na rugosidade mostraram que a maior diferença foi na região cervical para Bulk Fill Flow SDR (p=0,014) e Tetric N-Ceram Bulk Fill (p=0,003), com aumento após o desafio ácido. Conclusão após desafio ácido, as resinas compostas bulk-fill flow apresentaram alterações semelhantes às apresentadas pela resina composta convencional nanoparticulada.


Subject(s)
Statistics, Nonparametric , Composite Resins , Dental Caries , Dental Restoration, Permanent , Light-Curing of Dental Adhesives , Hardness Tests
9.
Rev. odontol. UNESP (Online) ; 51: e20220043, 2022. tab
Article in Portuguese | LILACS, BBO | ID: biblio-1424239

ABSTRACT

Introdução: a inovação dos métodos de fotopolimerização foi proposta na tentativa de diminuir o estresse de contração de polimerização das resinas compostas e proporcionar maior conforto ao paciente, reduzindo o tempo de atendimento odontológico. Objetivo: avaliar a microdureza de duas resinas compostas nanoparticuladas submetidas a diferentes técnicas de polimerização. Material e método: quarenta espécimes foram divididos em quatro grupos (n=10) da seguinte forma: Filtek Z350 XT® + técnica imediata (GI); Filtek One Bulkfill® + técnica imediata (GII); Filtek Z350 XT® + técnica de pulso tardio (GIII); Filtek One Bulkfill® + técnica de pulso tardio (GIV). Após o armazenamento em água destilada à temperatura ambiente, os corpos de prova foram direcionados para a medição de microdureza. Utilizou-se teste T para comparação de técnicas e teste Two-Way ANOVA para calcular os efeitos das resinas compostas, técnicas de polimerização e interações referentes à variável dependente (p ≤0,05). Resultado: a resina Filtek Z350 XT® apresentou maior dureza na técnica imediata (GI - 312,45 ± 64,37) e pulso tardio (GIII - 244,50 ± 75,63) comparado à resina Filtek One Bulkfill®, em ambas as técnicas. Observaram-se maiores valores de dureza referentes à técnica imediata, com diferença estatística significativa em relação à resina testada (p = 0,04 - Filtek Z350 XT®; p = 0,03 - Filtek One Bulkfill®). Ambos os fatores isolados (resina e técnicas) apresentaram efeito nos valores de microdureza (p = 0,02 e p < 0,01, respectivamente). Conclusão: a técnica convencional demonstrou atingir maiores valores de dureza quando comparada à técnica de polimerização alternativa.


Introduction: the innovation of photopolymerization methods was proposed in an attempt to reduce the polymerization shrinkage stress of composite resins and also provide more comfort to patient reducing the chair time. The aim of this in vitro study was to assess the microhardness of two nanofilled composite resins subject to different curing techniques. Objective: assess the microhardness of two nanofilled composite resins subject to different curing techniques. Material and method: forty specimens were divided into four groups (N=10) as follows: Filtek Z350 XT® + immediate technique (GI); Filtek One Bulkfill® + immediate technique (GII); Filtek Z350 XT® + delayed pulse technique (GIII); Filtek One Bulkfill® + delayed pulse technique (GIV). After storage in distilled water at room temperature the specimens were assessed for microhardness measurement. T-test was used for comparison of techniques and two-way ANOVA used to calculate the effects of composite resins, curing techniques and their interactions on dependent variable (p set at 0.05). Result: Filtek Z350 XT® resin presented greater hardness on immediate technique (GI - 312,45 ± 64.37) and delayed pulse (GIII - 244,50 ± 75.63) compared to Filtek One Bulkfill® under both techniques. Overall, it was observed greater hardness values under immediate technique with a significant statistical difference apart of tested resin (p = 0.04 - Filtek Z350 XT®; p = 0.03 - Filtek One Bulkfill®). Both isolated factors (resin and techniques) presented effect on microhardness values (p = 0.02 and p < 0.01, respectively). Conclusion: the conventional technique demonstrated to reach higher hardness values when compared to the alternative polymerization technique


Subject(s)
In Vitro Techniques , Analysis of Variance , Composite Resins , Light-Curing of Dental Adhesives , Hardness Tests
10.
Braz. j. oral sci ; 20: e211656, jan.-dez. 2021. tab
Article in English | BBO, LILACS | ID: biblio-1253734

ABSTRACT

Aim: This study evaluated the water sorption and solubility of a light-cured resin cement, under four thicknesses and four opacities of a lithium disilicate ceramic, also considering three light-emitting diode (LED) units. Methods: A total of 288 specimens of a resin cement (AllCem Veneer Trans ­ FGM) were prepared, 96 samples were light-cured by each of the three light curing units (Valo ­ Ultradent / Radii-Cal ­ SDI / Bluephase II ­ Ivoclar Vivadent), divided into 16 experimental conditions, according to the opacities of the ceramic: High Opacity (HO), Medium Opacity (MO), Low Translucency (LT), High Translucency (HT), and thicknesses (0.3, 0.8, 1.5, and 2.0 mm) (n = 6). The specimens were weighed at three different times: Mass M1 (after making the specimens), M2 (after 7 days of storage in water), and M3 (after dissection cycle), for calculating water sorption and solubility. Results: The higher thickness of the ceramic (2.0 mm) significantly increased the values of water sorption (44.0± 4.0) and solubility (7.8±0.6), compared to lower thicknesses. Also, the ceramic of higher opacity (HO) generated the highest values of sorption and solubility when compared to the other opacities, regardless of the thickness tested (ANOVA-3 factors / Tukey's test, α = 0.05). There was no influence of light curing units. Conclusion: Higher thicknesses and opacities of the ceramic increased the water sorption and solubility of the tested light-cured resin cement


Subject(s)
Ceramics , Cementation , Resin Cements , Light-Curing of Dental Adhesives
11.
RFO UPF ; 26(2): 299-312, 20210808. tab
Article in Portuguese | LILACS, BBO | ID: biblio-1452536

ABSTRACT

Objetivo: Várias fontes de luz têm sido utilizadas desde que os materiais fotoativados foram introduzidos na odontologia. Diodos emissores de luz (LEDs) se popularizaram como a principal opção para a polimerização dos materiais restauradores. O objetivo nessa revisão da literatura foi avaliar a influência das fontes de luz emitidas por diodo (LEDs) de segunda e terceira geração sobre a dureza de compósitos restauradores. Revisão de literatura: Nas bases de dados PubMed e Google Scholar foram pré-selecionados 239 artigos na língua inglesa entre os anos de 2010 e 2020, utilizando os termos: lightcuring, LED light sources, and dental LEDs. Dos 239 artigos inicialmente selecionados, 37 artigos foram avaliados devido aos critérios de inclusão/exclusão no estudo. Considerações finais: Vários estudos apontaram diferenças importantes na dureza dos compósitos restauradores testados, tanto na superfície de topo quanto na base. No entanto, essas diferenças estavam mais associadas a características como: estado de conservação do LED, irradiância, tempo de ativação, espectro de emissão dos aparelhos e sua compatibilidade ao fotoiniciador presente no compósito. Assim, podemos considerar que o monitoramento das condições do aparelho, e a escolha correta da fonte de luz de acordo com o compósito a ser utilizado são essenciais para maximizar a dureza dos compósitos restauradores, pois embora os aparelhos de terceira geração sejam preferencialmente indicados para compósitos com fotoiniciadores alternativos, os aparelhos que emitem luz azul apresentam vantagens quando o compósito é ativado apenas pela Canforoquinona.(AU)


Objective: Several light sources have been used since the light-curing materials were introduced in dentistry. Light-emitting diodes (LEDs) have become popular as the main option for the polymerization of restorative materials. This literature review aimed to evaluate the influence of second and third generation Light-emitting Diode (LEDs) sources on the hardness of restorative composites. Literature Review: In the PubMed and Google Scholar databases, 239 scientific papers in English were pre-selected between 2010 and 2020 using light-curing, LED light sources, and dental LEDs. After reading, 37 articles were selected to compose the review. Several studies have pointed out significant differences in the hardness of the tested restorative composites, both on the top and base surfaces. However, these differences were more associated with characteristics such as: LED conservation conditions, irradiance, curing time, the emission spectrum of the devices and their compatibility with the photoinitiator used in the composite. Final Considerations: Thus, it can be considered that monitoring the condition of the device and the correct choice of light sources according to the composite to be used is essential to maximize the hardness of the restorative composites, because although third-generation devices are preferably indicated for composites with alternative photoinitiators, devices that emit blue light have advantages when the composite is activated only by Camphorquinone.(AU)


Subject(s)
Humans , Composite Resins/chemistry , Curing Lights, Dental , Hardness , Dental Materials/chemistry , Light-Curing of Dental Adhesives/methods , Polymerization
12.
RFO UPF ; 26(2): 179-184, 20210808. tab
Article in Portuguese | LILACS, BBO | ID: biblio-1443768

ABSTRACT

Este estudo avaliou a cor de duas resinas compostas universais produzidas por diferentes fabricantes. Noventa e seis espécimes das resinas compostas Filtek Z350XT (3M ESPE) e IPS Empress Direct (Ivoclar Vivadent) (n=48 cada) da cor A2E foram confeccionados com 5 mm de diâmetro X 6 mm de altura. Cada camada de 2 mm de espessura de resina inserida foi fotoativada com uma unidade fotoativadora LED com 900 mW/cm2 por 20 s. Os espécimes foram polidos com o sistema Sof-lex Pop-On (3M ESPE). A cor foi aferida com um espectrofotômetro digital portátil Easyshade (Vita Zahnfabrik, Bad Säckingen), com base nos eixos tridimensionais do sistema CIEL*a*b*, e sua diferença entre as resinas foi determinada em cada eixo, calculando o seu respectivo Δ (ΔL*, Δa* e Δb*) e os parâmetros de variação total de cor ΔE* e ΔE00. A diferença de cor entre as resinas em cada eixo foi analisada estatisticamente pelo Teste t de amostras independentes (α=0,05), além de considerar os limiares de 50%:50% de perceptibilidade e aceitabilidade da variação total de cor. Diferenças estatisticamente significativas foram observadas no ΔL* e no Δb* (p<0,001). Os valores de ΔE foram de três a quatro vezes superiores ao limite de perceptibilidade e em até duas vezes ao limite de aceitabilidade da variação total de cor. Verificou-se que diferenças importantes de cor podem ocorrer em resinas da mesma cor, porém, de fabricantes diferentes. Essas diferenças podem ser visualmente perceptíveis e acima dos limites de aceitabilidade, podendo comprometer o resultado estético da restauração.(AU)


This study assessed the color of two universal composites produced by different manufacturers. Ninety-six specimens of Filtek Z350XT (3M ESPE) and IPS Empress Direct (Ivoclar Vivadent) (n=48 each) colored A2E were made with 5 mm of diameter X 6 mm of height. Each 2 mm-thick composite layer inserted was light cured with a LED light curing unit with 900 mW/cm2 for 20 s. The specimens were polished with Sof-lex Pop-On (3M ESPE). The color was measured with a portable digital spectrophotometer Easyshade (Vita Zahnfabrik, Bad Säckingen) based on the tridimensional axes of the CIEL*a*b* system, and the difference between composites was determined in each axis by determining the respective Δs (ΔL*, Δa* e Δb*), along with the parameters for total color variation ΔE* and ΔE00. The color difference between composite in each axis was analyzed statistically using the t-test (α=0,05), besides considering the 50%:50% thresholds for visual perceptibility and acceptability of total color variation. Statistically significant differences were observed in ΔL* and Δb* (p<0.001). The ΔE values were three to four times higher than the perceptibility threshold and twice higher than the acceptability threshold for total color variation. Relevant color differences may occur in composites of the same color, yet, made by different manufacturers. These differences may be visually perceptible and higher than acceptance limits, and may compromise the esthetic result of dental restorations.(AU)


Subject(s)
Color , Composite Resins/chemistry , Reference Values , Time Factors , Materials Testing , Colorimetry , Light-Curing of Dental Adhesives
13.
Odovtos (En línea) ; 23(1)abr. 2021.
Article in English | LILACS, SaludCR | ID: biblio-1386506

ABSTRACT

Abstract: The aim of this study was to evaluate and compare the effects of different light sources on shear bond strength when bulk-fill composite was used for the repair of different composite resins. A total of 126 samples made from six resin composites with different properties were aged (thermal-cycling with 5000 cycle), exposed to the same surface treatments and adhesive procedure. Then, they were repaired with a bulk-fill composite. At the polymerization step, each group was divided into three subgroups (n=7) and light cured with a QTH light source for 40s and two different LED light sources for 20s. Subsequently, the specimens were aged in distilled water at 37 ºC for 4 weeks and then subjected to shear bond strength test. Then, the specimens were examined under a stereomicroscope to identify modes of failure and visualized by Scanning Electron Microscope. Data obtained from the study were analyzed using ANOVA and Tukey HSD Test (α=0.05). In all groups, the light curing units had an impact on shear bond strength (p<0.05). Among the study groups, the greatest bond strength values were observed in the specimens repaired using the LED and the specimens repaired with the QTH light curing unit had the lowest bond strength values. It was concluded that the content of composite resins and light curing units may influence bond strength of different composites repaired with the bulk-fill composite.


Resumen: El objetivo de este estudio fue evaluar y comparar los efectos de diferentes fuentes de luz sobre la resistencia de la unión al cizallamiento cuando se utiliza una resina bulk-fill para la reparación de diferentes resinas compuestas. Se envejecieron un total de 126 muestras fabricadas con seis compuestos de resina con diferentes propiedades (ciclo térmico con 5000 ciclos), expuestas a los mismos tratamientos de superficie y procedimiento adhesivo. Luego, fueron reparadas con una resina bulk- fill. En el paso de polimerización, cada grupo fue dividido en tres subgrupos (n=7) y fotopolimerizado con una fuente de luz QTH por 40s y dos fuentes de luz LED por 20s. Posteriormente, los especímenes se envejecieron en agua destilada a 37 ºC durante 4 semanas y luego se sometieron a una prueba de resistencia adhesiva de cizalla. Luego, los especímenes fueron examinados bajo un estereomicroscopio para identificar los modos de falla y visualizados por el Microscopio Electrónico de Barrido. Los datos obtenidos del estudio fueron analizados usando el ANOVA y la prueba Tukey HSD (α=0.05). En todos los grupos, las unidades de fotopolimerización tuvieron un impacto en la fuerza de adhesión al cizallamiento (p<0,05). Entre los grupos de estudio, los mayores valores de fuerza de adhesión se observaron en los especímenes reparados utilizando el LED y los especímenes reparados con la unidad de fotopolimerización QTH tuvieron los valores de fuerza de adhesión más bajos. Se llegó a la conclusión de que el contenido de las resinas compuestas y las unidades de fotopolimerización pueden influir en la fuerza de adhesión de los diferentes compuestos reparados con resinas bulk-fill.


Subject(s)
Light-Curing of Dental Adhesives/methods , Dental Restoration Repair
14.
Rev. Asoc. Odontol. Argent ; 109(1): 3-8, ene.-abr. 2021. ilus, tab, graf
Article in Spanish | LILACS | ID: biblio-1255177

ABSTRACT

Objetivo: Comparar clínicamente el comportamiento, el tiempo operatorio requerido, el costo y la dificultad de diferentes técnicas de restauración en piezas primarias, empleando ionómero vítreo fotoactivado (IVF) polvo/líquido, con y sin uso de acondicionamiento dentinario, y en cápsulas, con acondicionamiento. Materiales y métodos: El diseño de este estudio fue experimental y comparativo. Se realizaron, en 18 pacientes de 7±2 años, 33 restauraciones con IVF de una o más piezas primarias vitales con lesiones amelodentinarias en 1 o 2 superficies. Según su día de concurrencia a la Cátedra de Odontología Integral Niños, se empleó: A) IVF polvo/líquido, con acondicionamiento (3M™ VitremerTM); B) IVF polvo/líquido, sin acondicionamiento (3M™ VitremerTM); y C) IVF en cápsulas, con acondicionamiento (Riva Light Cure). Las restauraciones fueron evaluadas clínicamente al inicio y a los 12 meses según los siguientes criterios: pérdida total, pérdida total con caries, requerimiento de reemplazo por pérdida parcial, requerimiento de reemplazo por caries, aceptable con deterioro, en condiciones. El grado de dificultad se analizó utilizando una planilla diseñada para tal fin. El tiempo operatorio requerido se midió sin considerar el tiempo de inserción. Resultados: El tiempo operatorio requerido fue de 2 minutos, 15 segundos en A; 1 minuto, 25 segundos en B; y 1 minuto, 10 segundos en C, sin considerar el tiempo de inserción. El costo fue 61,11% mayor para C. La dificultad fue de 3,2±0,6 para A y B, y de 1,5±0,7 para C (ANOVA; P<0,001). El comportamiento clínico no registró diferencias significativas entre los grupos (Fisher; P=0,339). Conclusión: Los ionómeros de restauración fotoactivados encapsulados utilizados en este estudio presentaron menor dificultad de manipulación, mayor costo y similar comportamiento clínico a un año que las presentaciones polvo-líquido, con o sin uso de acondicionamiento previo en piezas primarias (AU)


Aim: To assess the clinical performance, operative time required, cost and technical difficulties of different restorative techniques in primary teeth, using light cured glass ionomers (LCG), powder/liquid, with and without dentin conditioning and light cured glass ionomer in capsules with conditioning. Materials and methods: The design of this study was experimental and comparative. 33 restorations with LCG were performed in 18 patients, 7 ± 2-years-old, in one or more vital primary teeth with carious lesions involving one or more tooth surfaces. Patients were assigned to one of the three groups according to the day of the week in which they attended to the Pediatric Department of the Dental School: A) LCG powder/liquid, with conditioning (3M™ VitremerTM); B) LCG powder/liquid without conditioning (3M™ VitremerTM); and C) LCG in capsules with conditioning (Riva Light Cure). The restorations were clinically evaluated at baseline and after 12 months according to the following criteria: complete loss of the restoration, complete loss with caries, need of replacement because of partial loss, need of replacement because of caries, good condition with some wear and good condition. Technical difficulties were analyzed using a data sheet designed for that purpose. The operative time required was evaluated without considering the insertion time. Results: Time operative time required was 2 minutes 15 seconds in A, 1 minute 25 seconds in B and 1 minute 10 seconds in C. Cost was 61.11% higher for C. Difficulty was 3.2±0.6 for A and B and 1.5±0.7 for C (ANOVA; P<0.001). No significant differences were observed among the three groups in relation to the clinical performance (Fisher; P=0.339). Conclusions: In these 12 months, study in primary teeth, the light cured glass ionomers used dispensed in capsules showed to be the easiest to handle, had higher cost and similar clinical performance than the powder liquid presentations with and without dentin conditioner (AU)


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Tooth, Deciduous , Dentin-Bonding Agents , Dental Care for Children/methods , Dental Restoration, Permanent/methods , Glass Ionomer Cements/therapeutic use , Argentina , Schools, Dental , Prospective Studies , Analysis of Variance , Clinical Trial , Costs and Cost Analysis , Light-Curing of Dental Adhesives , Time-to-Treatment
15.
Braz. dent. j ; 32(1): 78-84, Jan.-Feb. 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1180726

ABSTRACT

Abstract The objective of this study was to evaluate the effect of the exposure reciprocity law of a multi-wave light-emitting diode (LED) on the light transmittance (LT), depth of cure (DOC) and degree of conversion in-depth (DC) of a bulk fill composite. A bulk fill composite (EvoCeram® bulk fill, Ivoclar Vivadent) was photoactivated using the multi-wave LED (VALO™ Cordless, Ultradent). The LED was previously characterized using a spectrophotometer to standardize the time of exposure when using the Standard or Xtra-Power modes with the same radiant exposure of 20J/cm2. LT was evaluated through samples of the bulk fill composite every millimeter till 4 mm in-depth. DOC was evaluated according to the ISO 4049. DC of the central longitudinal cross-section from each sample of the DOC test was mapped using FT-NIR microscopy. Data were statistically analyzed according to the experimental design (α=0.05; ß=0.2). The radiant exposure in the violet wavelength range for Standard and Xtra-Power was 4.5 and 5.0 J/cm2, respectively; for the blue wavelength range the radiant exposure for Standard and Xtra-Power was 15.5 and 15.0 J/cm2, respectively. There was no statistical difference in the DOC using Standard or Xtra-Power light-curing modes, but the DOC was lower than the claimed by the manufacturer (4 mm). The DC was not significantly affected by the light-curing mode up to 4 mm in depth (p>0.05). According to exposure reciprocity law, the reduction in exposure time using the same radiant exposure did not affect the depth of cure of the bulk fill composite.


Resumo O objetivo deste estudo foi avaliar o efeito da lei de reciprocidade de um diodo emissor de luz (LED) multi-wave na transmitância de luz (LT), profundidade de cura (DOC) e grau de conversão em profundidade (DC) de um compósito bulk fill. Material e Métodos: Um compósito bulk fill (EvoCeram®, Ivoclar Vivadent) foi fotoativado utilizando um LED multi-wave (VALO ™ Cordless, Ultradent). O LED foi previamente caracterizado usando um espectrofotômetro para padronizar o tempo de exposição utilizando os modos Standard ou Xtra-Power com a mesma dose de energia de 20 J/cm 2. A LT foi avaliada através de amostras do compósito bulk fill a cada milímetro até 4 mm de profundidade. O DOC foi avaliado de acordo com a ISO 4049. O DC foi realizado em forma de mapeamento da seção transversal longitudinal central de cada amostra do teste de DOC utilizando microscopia FT-NIR. Os dados foram analisados estatisticamente de acordo com o delineamento experimental (α=0,05; ß=0,2). A exposição radiante na faixa de comprimento de onda violeta para os modos Standard e Xtra-Power foi de 4,5 e 5,0 J/cm2, respectivamente; e para a faixa de comprimento de onda azul, a exposição radiante para os modos Standard e Xtra-Power foi de 15,5 e 15,0 J/cm2, respectivamente. Não houve diferença estatística no DOC utilizando os modos de fotopolimerização Standard ou Xtra-Power, mas o DOC foi menor do que o reivindicado pelo fabricante (4 mm). O DC não foi afetado significativamente pelo modo de fotopolimerização até 4 mm de profundidade (p>0,05). De acordo com a lei de reciprocidade da exposição, a redução no tempo de exposição utilizando a mesma exposição radiante não afetou a profundidade de cura do compósito bulk fill.


Subject(s)
Composite Resins , Curing Lights, Dental , Surface Properties , Materials Testing , Color , Light-Curing of Dental Adhesives , Polymerization , Hardness
16.
Article in English | LILACS, BBO | ID: biblio-1250463

ABSTRACT

ABSTRACT Objective: To evaluate in vitro the flexural strength of two newer composite resin materials. Material and Methods: Twenty-four samples were equally divided into two groups: G1 - Brilliant EverGlow and G2: Brilliant NG. The rectangular blocks of 25 mm in length, 2 mm in width and thickness were prepared from two composite materials. Blocks were created by applying composites to a customized split mold and formed between two parallel glass plates. Before light-curing, blocks were covered with Mylar strips and rinsed for 10 seconds in water. Subsequently, they were stored in distilled water for 24 hours at 37ºC and 100% humidity before testing. Each sample was placed within a suitable framework of aluminum. The length of gap between the support was 21 mm and the speed of crosshead at 1 mm/minute. The data were subjected to an independent t-test. The level of significance was set at p <0.05. Results: A less flexural strength was observed in G1 (77.43 Mpa) compared to G2 (118.70 Mpa) (p<0.001). Conclusion: Universal nanohybrid composite resin material was found to have greater flexural strength than universal submicron hybrid composite material.


Subject(s)
Materials Testing , Composite Resins , Dental Materials , Nanocomposites , Flexural Strength , In Vitro Techniques/methods , Data Interpretation, Statistical , Light-Curing of Dental Adhesives/methods , India
17.
São José dos Campos; s.n; 2021. 73 p. ilus, graf, tab.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1361284

ABSTRACT

Os fotopolimerizadores vêm sendo utilizados como dispositivos fundamentais na Odontologia para confecção de restaurações. No entanto, a etapa de fotopolimerização da resina composta inadequada pode afetar a união entre o material restaurador e o substrato. No caso dos agentes cimentantes resinosos a dificuldade está na limitação do local de incidência da luz. Em cimentações de retentores intrarradiculares pré-fabricados, normalmente são utilizados os cimentos de ativação química ou dupla ativação, devido a limitações anatômicas. Portanto, o objetivo deste trabalho foi avaliar o efeito da emissão de luz com fibra óptica, na cimentação de retentor intrarradicular experimental capaz de fotoativar em toda a extensão do conduto radicular. No estudo foi confeccionado um protótipo de ponta acessória em fibra óptica para fonte transmissora de luz que acoplado a um aparelho fotoativador (Bluephase, Ivoclar, Brasil) transmite a luz pelo interior do conduto radicular. Desta forma foram confeccionados em parceria com a empresa Angelus, retentores experimentais vazados ao longo dos seus eixos em fibra de vidro parcialmente opacos. Para simulação do conduto radicular foram utilizadas 80 amostras de resina G10 seccionadas no tamanho de 10 mm de largura por 14 mm de altura (n=80). Cada amostra foi perfurada ao centro nas seguintes dimensões: diâmetro de 3,0 mm e 10 mm de altura. Para cimentação dos retentores intrarradiculares foram utilizados cimento resinoso fotoativado ou dual. A fotoativação foi realizada diretamente com a ponta do aparelho fotoativador ou utilizando o dispositivo experimental transmissor de luz. As amostras foram analisadas imediatamente ou após o envelhecimento térmico de 10.000 ciclos. Para análiseda resistência de união as amostras foram seccionadas em 3 partes, com 2 mm cada (coronal, média e apical) e submetidas aos testes de resistência de união por push out, seguido da análise estereomicroscópica e análise espectroscópica no infravermelho transformada por Fourier (FT-IR). O dispositivo experimental transmissor de luz foi avaliado quanto a sua irradiância, e esta obteve 50% da energia quando comparada com obtida diretamente da ponteira do fotoativador. Após testes mecânicos, os resultados encontrados foram submetidos aos testes estatísticos, Anova com 3 fatores (cimento x fotoativação x profundidade) e Anova 2 fatores (envelhecimento x cimento), seguida de teste Tukey com nível de significância de 5%. Nos resultados de resistência houve diferença estatística entre os tipos de cimentos, profundidade, fotoativação e interação entre oscimentos e a profundidade, sendo que os grupos cimentados com os cimentos fotoativados e com o dispositivo houve uma maior resistência de união na porção média e apical. Com relação ao grau de conversão houve uma maior conversão e a análise estereomicroscópica apresentou maior falha adesiva na porção apical, independente da realização do envelhecimento. Portanto, a utilização do dispositivo obteve resultados promissores e o retentor intrarradicular experimental contribuiu para aumentar a adesão entre o cimento e o substrato em sua porção mais apical.


Photopolymerizers have been used as a fundamental device in dentistry for making restorations. Nonetheless, the stage for the photopolymerization of the composite resin is critical and can affect the adhesion between the restorative material and the substrate. In the case of resin cementing agents, the difficulty lies in limiting the location of the incidence of light. In cementations of prefabricated intraradicular retainers, chemical activation or double activation cements are normally used, due to anatomical limitations. Therefore, the objective of this work was to evaluate the effect of light emission with optical fiber in the cementation of experimental intraradicular retainer capable of photoactivating in the entire length of the root canal. In the study, a prototype of fiber optic accessory tip for light transmitting source was made, which coupled to a photoactivator device (Bluephase, Ivoclar, Brazil) transmits the light inside the root canal. Thus, they were made in partnership with the company Angelus, experimental retainers cast along their axes in partially opaque fiberglass. For simulation of the root canal were used 80 samples of resin G10 sectioned in size 10mm wide by 14mm high (n=80). Each sample was drilled in the center in the following dimensions: diameter 3.0 mm and height 10 mm. For the cementation of the intraradicular seals, light-cured or dual resin cement was used. The photoactivation was performed directly with the tip of the photoactivator device or using the light transmitting experimental device. The samples were analyzed immediately or after thermal aging of 10,000 cycles. For bond strength analysis, the samples were sectioned into 3 parts, with 2 mm each (coronal, mean and apical) and submitted to the bond strength tests by push out, followed by the stereomicroscopic analysis and infrared spectroscopic analysis by Fourier (FTIR). The Light Transmitting Experimental Device was evaluated for its irradiance and obtained 50% of the energy when compared to that obtained directly from the tip of the photoactivator. After mechanical tests, the results found were submitted to the statistical tests Anova with 3 factors (cement x photoactivation x depth) and Anova 2 factors (aging x cement), followed by Tukey's test with a significance level of 5%. In resistance results, there was a statistical difference between the types of cements, depth, photoactivation and interaction between the cements and depth, and the groups cemented with the photoactivated cements and the device had a greater bond strength in middle and apical portion. Regarding the degree of conversion, there was a greater conversion and the stereomicroscopic analysis, it showed greater adhesive failure in the apical portion, regardless of the performance of aging. Therefore, the use of the device obtained promising results and the experimental intraradicular retainer contributed to increase the adhesion between the cement and the substrate in its most apical portion.


Subject(s)
Cementation , Dental Equipment , Dental Pins , Light-Curing of Dental Adhesives , Optical Fibers , Biocompatible Materials , Materials Testing , Analysis of Variance , Dental Cements
18.
Braz. dent. sci ; 24(4): 1-9, 2021. tab, ilus, graf
Article in English | LILACS, BBO | ID: biblio-1337615

ABSTRACT

Objective: The objective of this study was to characterize and correlate the absorption spectra of three photoinitiators [camphorquinone (CQ), diphenyl(2,4,6-trimethylbenzoyl) phosphine oxide (TPO) and phenylbis (2,4,6-trimethylbenzoyl)-phosphine oxide (BAPO)], using second or third-generation light curing units (LCU), and to evaluate the degree of conversion and the physical properties of an experimental resin adhesive. Material and methods: Second-generation (Radii-cal® and Emitter D®) and third-generation (Valo® Cordless and Bluephase N®) LCU were assessed regarding spectrum and irradiance rate of emitted light. Also, the photoinitiators (CQ, TPO and BAPO) were characterized by a light absorption spectrum assessed by UV-Vis spectroscopy, degree of conversion and yellowing effect. Statistical analyzes considered two-way ANOVA and post-hoc Tukey test. Results: BAPO presented higher reactivity compared to TPO. Regarding degree of conversion of the photoinitiators activated by different light-curing units, the Emitter D® device promoted a high degree of conversion. BAPO presented the highest yellowing effect values. Conclusions: The emission and absorption characteristics of the photoinitiators were different. The polymerization reaction activated by the second-generation light-curing unit was reduced when using an experimental resin with photoinitiator TPO, and the third-generation light-curing unit showed a higher polymerization potential regardless of the photoinitiator. (AU)


Objetivo: Caracterizar e correlacionar os espectros de absorção de três fotoiniciadores [canforoquinona (CQ), difenil 2,4,6-trimetilbenzil óxido de fosfina (TPO) e óxido de di (2,4,6-trimetilbenzil) difenil fosfina (BAPO)], com unidades de fotoativação (LCU) de segunda ou terceira geração, e avaliar o grau de conversão e as propriedades físicas de um adesivo experimental. Material e métodos: LCU de segunda geração (Radii-cal® e Emitter D®) e terceira geração (Valo® Cordless e Bluephase N®) foram avaliadas quanto ao espectro e taxa de irradiância da luz emitida. Além disso, os fotoiniciadores (CQ, TPO e BAPO) foram caracterizados por um espectro de absorção de luz avaliado por espectroscopia UV-Vis, avaliado o grau de conversão dos adesivos e efeito de amarelamento. A análise estatística empregada foi ANOVA duas vias e teste post-hoc de Tukey. Resultados: BAPO apresentou maior reatividade comparado ao TPO. Em relação ao grau de conversão dos fotoiniciadores ativados por diferentes aparelhos fotopolimerizadores, o dispositivo Emitter D® promoveu um alto grau de conversão. BAPO apresentou os maiores valores de efeito de amarelamento. Conclusões: As características de emissão e absorção dos fotoiniciadores foram diferentes. A reação de polimerização ativada pelas unidades de fotopolimerização de segunda geração foi reduzida com o uso de uma resina experimental com fotoiniciador TPO. As unidades de fotopolimerização de terceira geração apresentaram maior potencial de polimerização independentemente do fotoiniciador. (AU)


Subject(s)
Light-Curing of Dental Adhesives , Curing Lights, Dental , Photoinitiators, Dental
19.
Acta odontol. latinoam ; 33(2): 82-89, Sept. 2020. graf
Article in English | LILACS | ID: biblio-1130737

ABSTRACT

ABSTRACT The aim of this study was to evaluate the degree of conversion, cytotoxicity, solubility and pH of photopolymerizable calciumbased cements submitted to preheating. The degree of conversion was analyzed by Fourier transform infrared, cytotoxicity by the MTT test and solubility through loss of mass. The data were subjected to statistical tests (ANOVA / Tukey's, p<0.05). The photopolymerizable materials showed a low degree of conversion, regardless of preheating. All materials caused a reduction in cell viability at 24 hours and 7 days, with the Dycal (control) being more cytotoxic. Heat had a positive effect on Biocal at 7 days. Dycal is the most soluble material. Heat had no effect on the solubility or pH of the polymerizable materials. It is concluded that photopolymerizable calcium-based cements have a low degree of conversion and are soluble, which results in mild to moderate cytotoxicity.


RESUMO O objetivo do presente estudo foi avaliar o grau de conversão, citotoxicidade, solubilidade e pH de cimentos à base de cálcio fotopolimerizáveis submetidos a pré-aquecimento. O grau de conversão foi analisado por espectroscopia no infravermelho com transformada de Fourier, a citotoxicidade pelo teste de MTT e a solubilidade através da perda de massa. Os dados foram submetidos a testes estatísticos (ANOVA/Tukey, p<0,05). Os materiais fotopolimerizáveis apresentaram baixo grau de conversão, independente do pré-aquecimento. Todos os materiais causaram redução da viabilidade celular nas análises de 24 horas e 7 dias, sendo que o Dycal (controle) apresentouse mais citotóxico e o calor apresentou efeito positivo sobre o Biocal na análise de 7 dias. O Dycal é o material mais solúvel e o calor não causou efeito na solubilidade e pH dos materiais polimerizáveis. Assim, conclui-se que os cimentos à base de cálcio fotopolimerizáveis apresentam baixo grau de conversão e são solúveis, que resulta em citotoxicidade suave e moderada.


Subject(s)
Humans , Calcium Hydroxide/toxicity , Cell Survival/drug effects , Dental Cements/chemistry , Pulp Capping and Pulpectomy Agents/toxicity , Calcium Hydroxide/chemistry , Calcium , Dental Cements/toxicity , Dental Pulp Capping , Light-Curing of Dental Adhesives , Photochemical Processes , Pulp Capping and Pulpectomy Agents/chemistry , Polymerization , Hydrogen-Ion Concentration
20.
Odovtos (En línea) ; 22(2)ago. 2020.
Article in English | LILACS, SaludCR | ID: biblio-1386480

ABSTRACT

Abstract: Aim: Sufficient polymerization remains as crucial for composites to prevent discoloration. Both LEDs and halogen units are used for polymerization and different curing modes are improved to overcome inadequate polymerization. This in vitro study investigated staining susceptibility of a nano-hybrid resin composite light-cured in different modes and immersed in different staining media. Methods: Disc-shaped specimens were prepared from nano-hybrid resin composite (Filtek Z550) and light- cured according to following modes: Halojen (GI), LED standard (GII), LED pulse (GIII) or LED ramp (GIV). Half of the specimens of each group (n=7) were stored in one of the staining media (red wine or coffee) for 10 min/day during experimental period. Measurements were performed using spectrophotometer according to CIEL*a*b system at baseline and on 7, 28 and 56 days. Colour differences (∆E) between groups were submitted to statistical analysis. Results: Regarding 7-day evaluation, colour change values of specimens immersed in coffee revealed no remarkable difference among curing modes (p>0.05); whereas specimens in GIV were significantly less stained compared to specimens in GII and GIII when immersed in red wine. Regarding 56- days of evaluation, specimens of GIV showed statistically significant colour change in red wine compared to other groups. However specimens in GI revealed the least staining after 56-days of coffee immersion, and this result was statistically different from LED groups. Conclusion: This study suggest that light-curing mode influences the staining susceptibility of the tested composite. Composites polymerized with halogen unit showed lower staining than all LED modes. Despite novel light sources, halogen units may still used reliably at clinics.


Resumen: Objetivo: La polimerización suficiente sigue siendo crucial para que los compuestos eviten la decoloración. Tanto los LED como las unidades halógenas se utilizan para la polimerización y se mejoran los diferentes modos de curado para superar la polimerización inadecuada. Este estudio in vitro investigó la susceptibilidad a la tinción de un compuesto de resina nano-híbrida curado a la luz en diferentes modos y se sumergió en diferentes medios de tinción. Métodos: Las muestras en forma de disco se prepararon a partir de un compuesto de resina nano-híbrida (Filtek Z550) y se curaron con luz de acuerdo con los siguientes modos: Halojen (GI), estándar de LED (GII), pulso de LED (GIII) o rampa de LED (GIV). La mitad de las muestras de cada grupo (n = 7) se almacenaron en uno de los medios de tinción (vino tinto o café) durante 10 minutos / día durante el período experimental. Las mediciones se realizaron utilizando un espectrofotómetro de acuerdo con el sistema CIEL * a * b en la línea de base y en 7, 28 y 56 días. Las diferencias de color (∆E) entre los grupos se sometieron a análisis estadístico. Resultados: Con respecto a la evaluación de 7 días, los valores de cambio de color de las muestras sumergidas en café no revelaron diferencias notables entre los modos de curado (p> 0.05); mientras que las muestras en GIV se tiñeron significativamente menos en comparación con las muestras en GII y GIII cuando se sumergieron en vino tinto. Con respecto a los 56 días de evaluación, las muestras de GIV mostraron un cambio de color estadísticamente significativo en el vino tinto en comparación con otros grupos. Sin embargo, las muestras en GI revelaron la menor tinción después de 56 días de inmersión en el café, y este resultado fue estadísticamente diferente de los grupos LED. Conclusión: este estudio sugiere que el modo de fotopolimerización influye en la susceptibilidad de tinción del material compuesto probado. Los compuestos polimerizados con una unidad halógena mostraron una tinción más baja que todos los modos LED. A pesar de las nuevas fuentes de luz, las unidades halógenas todavía pueden usarse de manera confiable en las clínicas.


Subject(s)
Tooth Discoloration/diagnosis , Composite Resins , Light-Curing of Dental Adhesives/instrumentation